Why measure the actual desk,
not just the lamp's output?
Published July 24, 2026· Harlowelife research and product team · Updated October 29, 2026
The key point
Rated lamp output is not the light a person receives at a task. Height, distance, angle, surface reflectance and room conditions change illuminance on the desk. The calibration approach places a movable sensor at the actual reading or keyboard position for a work-surface measurement.
Validation of a measurement method does not establish health outcomes. Those require production data and relevant human studies.
Four measures, four different questions
How much light reaches the desk, page or keyboard position?
Assess light from the person's viewing position, as well as on the horizontal desk.
Consider uniformity, flicker, glare, spectrum and actual working distance together.
Melanopic EDI is calculated using CIE S 026 from the spectrum and amount of light at the eye position. A work-surface lux reading alone does not provide this measurement.
Current evidence status
| Item | Current status | Publication commitment |
|---|---|---|
| Desk-sensor calibration procedure | Validation documentation pending review | Publish the calibration steps, applicable conditions and supporting validation records once reviewed. |
| Work-surface illuminance | Sample measurements published | See the SOLA Desk product page for the stated sample and test setup. Production-version results require separate confirmation. |
| Working-white color readings | Sample readings published | State the calculation methods, light setting and measurement conditions alongside the values. |
| Flicker and glare | Detailed evidence not presented on this page | Add the applicable methods, operating conditions and results when the supporting records are available. |
| Visual comfort over longer use | In research | Describe outcomes only after relevant human data exists. |
| Sleep, alertness and long-term well-being | In research | Not current product-benefit claims |
Research boundaries
The light reaching the eyes depends on the room, viewing position, spectrum and intensity. Timing, duration, previous light exposure and individual differences also matter. CIE S 026 defines relevant measurement quantities. Visual performance data and eye-level exposure should be reported separately from claims about human outcomes.
Key sources
Regional references for lighting professionals
Our measurement references and research sources are shared across markets. For workplace projects, use guidance that matches the location and task. The documents below cover different topics; they are not interchangeable standards or certifications of this product.
- United States — ANSI/IES RP-46-25: daytime indoor lighting and physiological responses
- Europe — EN 12464-1:2021: indoor workplace lighting
- Australia / New Zealand — AS/NZS 1680.1:2006: interior and workplace lighting
- Australia — WorkSafe Victoria: practical office lighting guidance
- United Kingdom — SLL (2026): integrative lighting position statement